Pages

OBDSTAR ODOMASTER & X300 PRO4

Tuesday, September 10, 2024

Erase Mercedes-Benz VGS2-NAG2 TCM Data with OBDSTAR DC706

 This is a tutorial on how to do Mercedes-BENZ SIEMENS VGS2-NAG2 TCM data erase with OBDSTAR DC706 ECU Tool by bench. By performing a data wipe on the Benz transmission, we can erase the existing coding data and immobilizer information.


OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data

Tools Required

OBDSTAR DC706

12V 5A Power Supply(DC)

Main Cable

P004 ECU Clone Jumper + Adapter

BENZ SIEMENS VGS2-NAG2 TCM

ECU Flasher >> TCM >> Latest Version >> BENZ SIEMENS/CONTINENTAL VGS2-NAG2

Click "Guide" & "Pinout" to check wiring diagram for connection.


OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data
OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data
OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data
OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data
OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data

After completing connection, select

Start >> BENCH + P004 >> OK

Click "Connect" to start.

Switch ignition off.

Switch ignition on.

Click "Data Erase".

Switch ignition off.

Switch ignition on.

Data erase successful.

Remember to disconnect after operation is completed.

Simple and easy done.


OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data
OBDSTAR DC706 Erase Benz SIEMENS VGS2-NAG2 TCM Data

www.obdexpress.co.uk


No comments:

Post a Comment